Embrayage du Convertisseur de Couple Modulateur Plongeur Kit de valve
Symptoms
High TCC slip RPM at increasing load
Overheated fluid
Slip codes
Cause
The plunger force is transferred onto the inner modulator valve. When the sleeve wears, the converter apply pressure is reduced and TCC slippage increases.
Correction
The Sonnax assemblies restore proper hydraulic clearances so fluid pressure can position the TCC modulator valve to fully apply lockup. The increasecd ratio assembly provides a firmer and quicker lockup feel.